This situation is mainly caused by damage to the growth point in the early stage, and factors such as heavy spraying at the seedling stage and discomfort in temperature and humidity can be caused. In this regard, vegetable farmers should start from two aspects in the management: 1. Remove the bottom side branches, keep the slightly upper side branches, and finally choose the head with good growth points to leave. 2. Foliar spray canola, Lime and other foliar fertilizers.
Disclaimer: Some articles on this website are transferred from the Internet. If the legal rights of a third party are involved, please inform this website for processing. phone
Specifications:
High Resolution Image
Liner Scanning Method
100% Bandwidth with Short-Pulse Technology
Safe in Operations
No Abrasion of Cornea
No Cross Infection
Convenient
More Probe Shells Offered
Easy to Exchange Probe Shell
Adjustable Focus by Probe Shell
Transducer: 35MHz/50MHz
Scan: Linear scan
Scanning Range: 16mm*10mm 35MHz
10mm*6.5mm 50MHz
Image pixel: 1024*655
Resolution: axial≤0.05mm, lateral≤ 0.1mm
Gain: 30-105 dB
SAB-200 A/B Scan with normal, vitreous body enhancement, retina observation mode, mainly used for diagnosis of intraocular diseases, display the location, shape range of the focus of infection and the relationship with the surrounding tissue. Can be diagnosed vitreous opacity, retinal detachment, eye base tumors etc. eye diseases. A scan is used to measure anterior chamber depth, lens thickness, axial length, calculate diopter of implant IOL as well.
B scan:
Frequency: 10MHz/20MHz (optional) ,Magnetic driven, noiseless
Scanning Mode: Sector Scanning
Magnify:Multi continuous magnification,Real-Time magnification
Resolution: Lateral ≤0.3mm;Vertical≤0.2mm
Geometry position precision: Lateral ≤10%;Vertical≤5%
Depth:60mm
Enhance the part of vitreous body and retina
Gain of probe:30dB-105dB
Scanning Angle:53°
Gray Scale: 256
False Color: Multi colors. OCT
measurement type: multigroup distances, perimeters and areas
Image postprocessing: multiple curves processing, Pseudo-color processing curve
Movies: 100 images movie review, AVI JPG format image output
A scan:
Frequency:10MHz, with LED
Depth: 40mm
Precision:±0.05 mm
Measurement: Anterior chamber depth, lens thickness, vitreous body length, total length and average
Eye mode: Phakic / Aphakic / Dense / Various IOL
IOL Formula: SRK-II, SRK-T, HOFFER-Q, HOLLADAY,BINKHORST-II, HAIGIS
Stat. Calculation: Average and standard deviation
Store: 10 Scanning results for each eye
Others:
Display Mode :B.B+B.B+A.A
Hint: preset keyword
Case Search:Multi-keywords
Working Platform: Windows XP.VISTA.WINDOWS7