Ice machine common fault handling method

When the ice machine is in use, it will inevitably have some minor faults. How to deal with the failure? The following are the common fault handling methods for the ice machine that are organized by Shanghai Bayu technicians.
First, the ice machine is too noisy
1. The ice machine fan is faulty.
2 , the reducer is faulty.
3 , the compressor is noisy
Second, wet ice borneol is not hard
1. The ambient temperature is too high, especially in summer.
2 , the machine has been repaired with more refrigerant.
3. The water supply of the ice machine water distribution tray is too large.
4 , the press power is insufficient.
Third, the ice machine compressor interrupted work
1. The voltage is too low. Check the power supply.
2 , the contact point burning contact is not good.
3 , system pressure protection.
4. The compressor starter is faulty.
5 , the condenser is too dirty, high voltage protection.
Fourth, the boot report system failure
1 , the phase sequence problem.
2. The power supply system is faulty.
3 , the control board is faulty
Five, the machine is running but not ice
1. The water in the water tray is not enough or no water.
2 , gear unit failure or geared motor.
3 , the system is blocked by ice. Dirty blockage, etc.
4 , ice machine snow leakage, insufficient pressure
5 , the ice is not thick enough
Sixth, water shortage alarm
1. The water supply joint filter is blocked.
2 , the water supply pipe is blocked.
3 , the inlet valve is blocked.
4. The drain valve leaks.
5 , the pump is faulty.
Seven, ice machine leaking
1. The water supply to the water inlet valve is too large.
2. The damaged water pipe is damaged.
3. The hose clamp is faulty.
4. The water level float valve is faulty.
Eight, ice machine production ice reduction
1. Capillary or expansion valve plugging.
2 , the system is too high in water and there is a slight ice block.
3. The ice machine condensing system is blocked.
4. Insufficient refrigerant or leakage.
5 , the evaporator is too dirty.
" Important Troubleshooting Methods for Ice Machines" is provided by Shanghai Bashu. For more information on ice machine, please visit: http://

Hepatitis B Surface Antigen/AntibodyTest

INTENDED USE
Used for the qualitative detection of Hepatitis B surface

antigen in serum/plasma.

PRINCIPLE

The sample mixing up colloidal-gold monoclonal antibody move along the membrane to the T line, and form the T line when the human serum/plasma and whole blood contains HBsAg according to the principle of double antibody sandwich method and gold immunochromatography assay, which is a positive result. Unreacted markers move forward continually
to combine with anti-mouse antibody and form a control line.

If the test line does not appear, it is a negative result.

MAIN COMPONENTS

Sample pad, colloidal gold marked pad, nitrocellulose membrane, absorbent paper and PVC board.

INTERPRETATION OF RESULTS
POSITIVE: Two distinct red lines appear. A red line in the
control region (C), and another red line in the test region (T). A pink to red line (T), even if it is very thin, indicates a positive
result.

NEGATIVE: A red line appears in the control region(C). No line
appears in the test region (T).

INVALID: No red lines appear or control line fails to appear.
Insufficient specimen volume or incorrect procedural
techniques are the most likely reasons. Review the procedure and repeat the test with a new test
device.
If the problem persists, discontinue using the kit and contact
your local distributor.
231

Hepatitis B Surface Antigen Test,Hepatitis B Test Kit,Medical Diagnostic Test Hepatitis B,Diagnostic Test Hbsag

Changchun ZYF science and technology CO.,LTD , https://www.zyf-medical.com