How to operate the electric batch torque tester

How to operate the electric batch torque tester , the electric batch torque tester is a very popular torque instrument, many people buy, but the salesman of the Zui near dry company will always receive an inquiry about how to operate the electric torque tester. It is found that many users are not very familiar with the operation of the electric batch torque tester. The problems in the operation process are also very strange. For this reason, the hard work for the editor has compiled a document for the operation of the electric torque tester. I hope I can help. everyone.

Electric batch torque tester operation method:

First of all: Before using the electric torsion tester, check whether the instrument is fully charged. If the battery is low, please charge it first (it can also be used when charging).

Secondly, the quadruple probe of the test object is placed in the bearing square hole of the tester, and the handle of the other end of the test object is used above the height adjustment block (if the length is not enough, the whole set of loading device can be freely adjusted) ).

Third: Turn on the power switch, the displayed torque value is zero. If it is not zero, press the clear button to clear the torque value.

After zui: Before the test, * need to set the upper and lower limits, zui small storage value, zui small peak hold value, automatic peak time, automatic shutdown time, gravity acceleration, etc.

1. Upper limit setting: The user sets the upper limit value and can freely set according to the need. When the upper limit value is reached, the automatic sound and light prompt is displayed, and the upper limit value is not higher than the full scale.

2. Lower limit setting: The user sets the lower limit value and can be freely set according to the need. The lower limit value is the automatic light prompt, and the lower limit value must not be higher than the set upper limit value.

3, zui small storage value setting: the user sets the small storage value of zui according to the storage needs, the data smaller than the value will not be stored.

4, Zui small peak hold value setting: the user according to the peak, automatic peak measurement needs to be freely set, data less than this value is not saved by the peak.

5. Automatic peak time setting: The user can freely set the time required to maintain the peak value according to the automatic peak measurement state from 1 second to 99 seconds.

6. Automatic shutdown time setting: In the no-operation state, the automatic shutdown time can be set freely from 0 minutes to 9 minutes (when set to 0 minutes, it means to cancel the automatic shutdown).

7. Gravity acceleration setting: The user can set the gravity acceleration value according to the position of the area. The machine defaults to 9.794.

8. Restore the initial settings: If the user operates improperly or changes the data multiple times, the data can be restored to the factory state by using this setting.

Electric batch torque tester picture